Sinumerik Alarm 380071 Profibus DP: no output slot available for base address %1 (size %2)
Parameters:
%1 = Logical base address of the requested area
%2 = Size of the area in bytes
Definitions:
An incorrect logical base address was specified for a digital or analog input. Either no slot has been configured for this base address or the requested area extends beyond the end of the slot. For length =1 it is a digital output, For length =2 it is an analog output.
Reactions:
– Alarm display.
– Interface signals are set.
– Channel not ready.
– NC Start disable in this channel.
Remedy:
Enter correct base addresses in the machine data:
• For length=1: Correct machine data MN_HW_ASSIGN_DIG_FASTOUT.
• For length=2: Correct machine data MN_HW_ASSIGN_ANA_FASTOUT.
• NCK restart If the error cannot be eliminated by this procedure, please make a note of the error text and contact the control system manufacturer.
Program Continuation:
Switch control OFF – ON.
References