Haas Parameter 786-797 COMMAND FIR FILTER ORDER


Haas Parameter 786-797 COMMAND FIR FILTER ORDER

Support finite impulse response (FIR) feature on Coldfire MOCON PC boards.Parameters are 786 to 797 for axes X, Y, Z, A, B, C, U, V, W, Sp, Lt, Ss in lathes. The parameter limits number of high frequency components in servo command. The parameter specifies degree of command FIR filter, which acts as low pass filter to smooth out high frequency component in the command profile. Maximum value is 128.