Mazak Alarm 215 CHUCK SYSTEM MALFUNCTION


Mazak Alarm 215 CHUCK SYSTEM MALFUNCTION

Description
An erroneous chucking action was detected during chucking operation.

Check and remedy
The chuck unit has failed to grip the material.
OR
The chuck open/close end sensor (SQ2/SQ3) is abnormal or faulty.

Mazak Alarm 215 CHUCK SYSTEM MALFUNCTION