Haas Setting 188/189/190 – G51 X/Y/Z SCALE


Haas Setting 188/189/190 – G51 X/Y/Z SCALE

Haas Setting Description
The axes can be scaled individually using the following new settings (must be a positive number).
Setting 188 = G51 X SCALE
Setting 189 = G51 Y SCALE
Setting 190 = G51 Z SCALE
However, if setting 71 has a value, then settings 188-190 are ignored, and the value in setting 71 is used for scaling. If the value for setting 71 is zero, then settings 188-190 are used. Note that when settings 188-190 are in effect only linear interpolation, G01, is allowed. If G02 or G03 is used, alarm 467 will be generated.

References

  1. Haas Lathe Operator’s Manual by Haas Automation, Inc.
  2. Haas Mill Operator’s Manual by Haas Automation, Inc.