Okuma Alarm-P 0709 Hardware exception


Okuma Alarm-P 0709 Hardware exception
Hardware exception was occurred.

Object
None

Character-string
Occurred RT thread name

Code
Hardware exception code

0x5555: CPU Diagnose error
0x8100:Divide by 0 error
0x8101:Unexpected Single Step Interrupt
0x8102:Unexpected NMI
0x8103:Unexpected Debug Interrupt
0x8104:Overflow error
0x8105:Array Bounds error
0x8106:Invalid Opcode error
0x8107:NPX Device not present
0x8108:Double Fault error
0x8109:Unknown Device error
0x810A:Invalid TSS error
0x810B:Segment not Present error
0x810C:Stack Fault error
0x810D:General Protection error
0x810E:Page Fault error
0x8110:Unknown Device error 1
0x8111:Alignment error

Probable Faulty Locations
1.Hardware failure
2.Software failure

Note
Alarm information is also displayed also in the console window.

Okuma Alarm-P 0709 Hardware exception