Okuma Alarm-P 0800 Spindle D/A control data file read


Okuma Alarm-P 0800 Spindle D/A control data file read
The NC failed to read the spindle D/A control data file.

Code
XY
X: Gear set number (The number where the error occurred first.X does not appear if Y = 1 to 6.)
Y=1 -> No data file
Y=2 -> Data file type is not PBU1.
Y=3 -> Larger data file size
Y=4 -> Improper data file size
Y=5 -> Gear set number does not match the data file size.
Y=6 -> Gear set number is not any of 1 to 4.
Y=7 -> Motor speed limit or spindle speed limit is 0.
Y=8 -> Max spindle speed is 0.

Probable Faulty Locations
Spindle D/A control data file creation error

Measures to Take
Create a correct spindle D/A control data file.

Okuma Alarm-P 0800 Spindle D/A control data file read