Okuma Alarm-P 0799 MCS Linear scale 1 error
Illegal data was detected in Liner scale 1(MITUTOYO).
Object
Axis
Character-string
None
Code
XXYYZZZZ
XX= Liner scale 1 status
bit7: alarm
bit6: communication error
bit2: communication error(every detection)
bit0: alarm code distinction bit (bit0=1: An alarm occurred in MITUTOYO scale.)
bit6: communication error
bit2: communication error(every detection)
bit0: alarm code distinction bit (bit0=1: An alarm occurred in MITUTOYO scale.)
YY=Liner scale 1
case of XX=88
bit7: over speed
bit6: communication error
bit5: EEPROM error
bit4: CPU error
bit3: electric capacity error
bit2: photo electron error
bit1: digit match error
bit0: initialize error
bit6: communication error
bit5: EEPROM error
bit4: CPU error
bit3: electric capacity error
bit2: photo electron error
bit1: digit match error
bit0: initialize error
case of XX=80
43: MITUTOYO scale no response
44: MITUTOYO scale ID error
44: MITUTOYO scale ID error
case of XX=C0
00-3F: Gateway receive error
46: REQ time over error
46: REQ time over error
ZZZZ= Liner scale 1 position data
position data of every 2mm pitch
Probable Faulty Locations
Linear scale 1
Corrective Action
Change Linear scale 1