Okuma Alarm-P 0834 MCS servo data error


Okuma Alarm-P 0834 MCS servo data error
Erroneous servo data has been transferred to MCS.

Object
Axis name or none

Character-string
None

Code
XXXXYYZZ
XXXX = ID number
YY = Parameter number
ZZ = Error content

01: Out of setting range
02: Set timing error
03: No data transfer
04: Calculation error
05: Others
06: Number of ID over

Probable Faulty Locations
– The servo data file does not match the MCS software version.
– NC software

Measures to Take
– Change the servo data file.

Okuma Alarm-P 0834 MCS servo data error