Okuma Alarm-P 0877 MCS Servo data error
The servo data sent from the NC for initialization or operation is not applicable to the inverter unit.
If this alarm occurs after change of inverter unit, the servo data file is not applicable to the inverter unit.
If this alarm occurs after adjustment or change of the servo data, the servo data is wrongly changed.
Object
Axis name or none (spindle)
Character-string
None
Code
XXXXYYYY
XXXX= Data ID number of the data that caused the error
YY= Data set number of the data that caused the error
ZZ= Error content
1: Out of setting range
2: Wrongly set timing
3: No transmission
4: Calculation error
5: Others
6: Number of ID over
2: Wrongly set timing
3: No transmission
4: Calculation error
5: Others
6: Number of ID over
Probable Faulty Locations
– Servo data file not compatible with inverter unit
– Inverter unit not compatible with NC software
– Inverter unit control board
– NC software