Okuma Alarm-P 0897 MCS Full abso scale error


Okuma Alarm-P 0897 MCS Full abso scale error
The full absolute scale has become unable to detect positional data.

Object
Axis name or none (spindle)

Character-string
None

Code
XXYYZZZZ
XX= Encoder error code depending on the encoder type
YY= Detailed encoder status. The status varies with the encoder type.
ZZZZ= Multi-turn position data. This data appears when the multi-turn position data has exceeded the rotating range.

XX = 0 (fixed)
YY = 1 (fixed)

ZZZZ = Multi-turn position data

Probable Faulty Locations
– Full absolute scale