Okuma Alarm-A 1121 PSC Optical scale encoder error


Okuma Alarm-A 1121 PSC Optical scale encoder error
An error was detected by the position encoder of optical scale.

Character-string
None

Code
XXYYZZ
XX:Value of the J-type endoder and value of the optical scale are too different.

bit1:It is too different by a negative sign.
bit0:It is too different by a positive sign.

YY:Pulse count value of optical scale

bit0:A-phase pulse and B-phase pulse have changed at the same time.

ZZ:The amplitude of the optical scale signal is wrong.

bit1:The amplitude of B-phase is wrong.
bit0:The amplitude of A-phase is wrong.

Probable Faulty Locations
– Breakdown of optical scale
– Breakdown of optical scale cable

Measures to Take
– Exchange of optical scale
– Exchange of optical scale cables

Okuma Alarm-A 1121 PSC Optical scale encoder error