Okuma Alarm-A 1197 MCS Full abso scale error
The full absolute scale has become unable to detect positional data.
Object
Axis name or none (spindle)
Character-string
None
Code
XXYYZZZZ
XX= Encoder error code depending on the encoder type
YY= Detailed encoder status. The status varies with the encoder type.
ZZZZ= Multi-turn position data. This data appears when the multi-turn position data has exceeded the rotating range.
XX = 0 (fixed)
YY = 1 (fixed)
ZZZZ = Multi-turn position data
Probable Faulty Locations
– Full absolute scale