Okuma Alarm-A 1299 Axis moved to sub-spindle interference distance
The issued command requires the sub spindle headstock (W-axis) and B-turret (ZB-axis) to come closer beyond the interference distance specified by the parameter.
(The machine of LT series conducts interference check between L and R spindles.)
(In the spec of Turret ZA-W IL. or ZA-W AXIS IL. conducts interference check between ZA-axis and W-axis.)
Code
1->Sub-spindle interference distance.
2->The Sub-spindle movement command exceeded Maximum distance between the Steady rest and the Tailstock.
3->The Sub-spindle movement command exceeded Minimum distance between the Steady rest and the Tailstock.
4->The Steady rest movement command exceeded Maximum distance between the Steady rest and the Tailstock.
5->The Steady rest movement command exceeded Minimum distance between the Steady rest and the Tailstock.
6->The Axis moved to the interference distance between the Turret and the R-spindle
Probable Faulty Locations
1)Program error
2)Parameter set value