Okuma Alarm-A 1522 Linear guide cover interference area


Okuma Alarm-A 1522 Linear guide cover interference area
Axis entered into a Linear guide interference position area.
Or it ordered in the linear guide cover interference area when the restart was executed.

Object
AXIS, SYSTEM

Code
1->Axis entered into a Linear guide interference position area.
2->It ordered in the linear guide cover interference area when the restart was executed.

Probable Faulty Locations
Axis entered into a Linear guide interference position area.

Measures to Take
Please move axis out from a Linear guide interference position area.