Okuma Alarm-A 1523 Workpiece weight data file not found
Work weight MCS data file specified by the parameter is not found.
Object
None
Code
XY
X:Sub Spindle
0->MCS Data File exists
1->No Chuck
2->Standard
3->Semi-standard
4->Heavy
1->No Chuck
2->Standard
3->Semi-standard
4->Heavy
Y:Main Spindle
0->MCS Data File exists
1->No Chuck
2->Standard
3->Semi-standard
4->Heavy
1->No Chuck
2->Standard
3->Semi-standard
4->Heavy
Probable Faulty Locations
Installation error
Software production error
Specification code error
Measures to Take
Reinstall the software or reissue the install disk.