Okuma Alarm-A 1723 Z-axis moved to spindle interference distance


Okuma Alarm-A 1723 Z-axis moved to spindle interference distance
1)ZA axis or ZB axis moved to the position where distance between ZA axis and ZB axes become smaller than setting valueof parameter long word No. 53 concerning new LT control.
2)ZB axis moved to the position which becomes smaller than setting value of parameter long word No. 56 by the condition whose XA axis and XB axis are not together concerning new LT control on Plus variable limit.
3)By the Spindlehead interlock specification, Z axis moved to the position which becomes smaller than setting value of parameter long word No. 57 by the condition whose X axis is on Plus variable limit.

Code
1->A case of mention above 1)
2->A case of mention above 2)
3->A case of mention above 3)

Probable Faulty Locations
1)Incorrect parameter long word No.53, 56, 57 setting.
2)Operation or program error.