Okuma Alarm-A 1732 Turret rotation interlock
Turret indexing was attempted when the turret indexing conditions are not met.
Code
XX
1->A turret index command was issued when the facing or OD tool clamp confirmation signal was OFF.
2->A T-command was issued when the touch setter is in advance position.
4->On the machine with Y-axis function, a turret index command was issued while the YS-axis is lower than the spindle center.
5->On the machine with NC turret, the simple tow-along tailstock is in connection.
8->A turret index command was issued while the YS-axis was located, in the machine coordinate system, lower than Spindle CENTER POSITION specified by the system parameter.
10->A turret index command was issued when the exchange arm is not at the perpendicular or retract position.
12->On the machine equipped with C-axis zero offset function by laser sensor, a turret index command was issued when the laser sensor retract confirmation input was OFF.
13->The turret index instruction which is divided impossibility was performed by the state which attached long tool (tool variety setting at ML with do tool) to turret T1 or the state which attached touch sensor of a measure within a machine specification.
14->When a long tool (tool type: ML) was mounted in the turret T1, a turret index command was issued with the shutter closed.
15->A turret index command was issued when the tool clamp confirmation signal was OFF. Or, the tool clamp confirmation signal was OFF during turret indexing.
16->Concerning special head tool turret-revolution interlock function, when there was special head tool in turret, turretrevolution order was performed.
17->B-turret index command was issued when B-turret is in interference area between B-turret and main spindle chuck.
18->A turret index command was issued when the finger chuck is unclamped.
19->B-turret index command was issued when B-turret is in prohibit condition of B-turret rotation.
20->Turret rotation command was issued when rolling-head was not opened.
21->A Semi-dry unit was not unclamp when a turret was indexing.
22->B-turret index command is issued, when B-turret Index Switch is set at Off.
23->A turret index command was issued when B-Axis mode.
24->Turret index command was issued when turret is in interference.
25->Turret rotation command was performed with special tool selection.
26->A turret index command was issued when the special tool ON. Or special tool ON command was issued when a turret was indexing.
27->A-turret index command was issued when A-turret is in interference area between A-turret and sub spindle chuck.
28->M spindle actual angle is not “M spindle angle for turret index” or M spindle angle is shifted from “M spindle angle for turret index” when turret is rotating.
29->A turret position was not on X/Z-axis plus variable limit when a turret indexing in manual mode.
30->For the 2-saddle specification and NC turret with brake specification, a turret rotation command was issued when axis brake release output was OFF and the other turret was not clamped.
31->When a long boring bar tool was mounted in the turret H1, a turret index command.
Probable Faulty Locations
1->A turret index command was issued while a tool was projected for tool change or manual tool loading/unloading.
The signal wire from the proximity switch is damaged.
The hydraulic solenoid valve for clamping face/OD tool is broken.
8->A turret indexing command was issued while the Y-axis is in a negative position in Y-axis mode.
12->A turret index command was issued with the laser sensor located in advance position, or the laser sensor retract confirmation LS is at fault.
Related Specifications
1)ATC multi-function machine, LT model, or lathe with Y-axis
3)C-axis origin offset or match port detection with laser sensor
30)2-saddle specification, NC turret with brake