Okuma Alarm-A 1792 Turret rotation interlock
Probable Faulty Locations
Turret Index Command is issued; when One of Turret Indexing Conditions is Not met. Turret Index Command, with Improper Index Range, is issued.
Code
5->Turret Index Command, with Improper Index Range, is issued.
Or, turret moved with improper index range.
6->Turret Index Command is issued; with Improper Index Range Parameter Data.
7->Turret Index Command is issued; when Turret is indexed at Improper Index Range.Or, turret moved with improper index range.
9->Turret A rotation command (T code) was executed with the X and Z axes of turret B not at the positive limit.
10->Turret B mounted steady rest; turret index command is issued,when turret index interlock parameter is not set.
14->Turret B Index Command is issued; when work rest is not down position.
15->Turret Index Command is issued; when work conveyor is not retract position.
16->Turret Index Command is issued;when ZB axis is not at Index position.
17->Turret B mounted steady rest; turret B index command (T code) is issued, when Steady Rest Switch is set at ON.
18->B-turret index command is issued, when B-turret index interlock parameter is set.
19->B-turret index command is issued with the W-axis not at the positive limit.
20->Turret Index Command is issued;when ZA axis is not at Index position.
Probable Faulty Locations
1)Operation error.