Okuma Alarm-A 1793 Side cover interlock
Code
1->At the time of automatic operation or MDI operational mode, a side cover is not close status.
2->At the time of manual interrupt mode, while main spindle rotating a side cover became not closed status or when a side cover was not close status main spindle rotation was performed.
3->When a side cover was not close status, a turret indexing order by a turret indexing button on the main control panel was performed.
4->When a side cover was not close status, main spindle rotation, axis movement were performed.
5->A turret indexing order by a turret indexing button on a sub control panel was performed at the time of the condition which is not door interlock ON and side cover close.
6->When a side cover was not close status, a spindle rotation order or M-spindle rotation order or C-axis rotation order was performed.
7->When a side cover was not close status, a axis movement order was performed.
8->When a side cover was not close status, a turret indexing order was performed.
9->At the time of NC running, a side cover is not close status.
10->When the left or right side cover was not close status, a turret indexing order by a turret indexing button on the sub control panel was performed.
Okuma Alarm-A 1793 Side cover interlock