Okuma Alarm-A 1804 Safety speed monitor output error


Okuma Alarm-A 1804 Safety speed monitor output error
The ER-PW signal was not correctly transmitted from the speed monitor to the loader power unit (MIP unit) due to a hardware circuit failure, e.g. fused relay. This alarm occurs when the following two input signals are kept ON or OFF for 0.5 second or longer.
Speed monitor alarm/(OGL) iSVLRER/ I.053D
Speed monitor alarm (OGL) iSVLRER I.053C

Probable Faulty Locations
1)A hardware circuit failure

Measures to Take
1)Check the hardware circuit from the speed monitor to the loader power unit (MIP unit).

Okuma Alarm-A 1804 Safety speed monitor output error