Okuma Alarm-A 8547 Drive jig unit interlock
Code
1->The main-spindle drive jig unit foward command was issued when W-axis was in designated position of W-axis.
2->The main-spindle drive jig unit oscillation command was issued when the main-spindle drive jig unit foward confirmation signal was OFF.
3->The main-spindle drive jig unit oscillation command was issued when W-axis was in designated position of W-axis.
4->The main-spindle drive jig unit oscillation command was issued during main-spindle rotation.
5->The sub-spindle drive jig unit oscillation command was issued when W-axis was not in designated position of W-axis.
6->The sub-spindle drive jig unit oscillation command was issued when the main-spindle drive jig unit foward confirmation signal was ON.