Okuma Alarm-A 8598 Ceiling door interlock


Okuma Alarm-A 8598 Ceiling door interlock
Any of the following operations is attempted while the ceiling door is open with the door interlock function ON.
Spindle rotation, axis movement, turret indexing, M-tool spindle rotation, peripheral unit operation, sub-spindle rotation.
Or an attempt is made to open the ceiling door in any of the above indicated state with the door interlock function ON.

Code
1->Spindle rotation
2->M-tool spindle rotation
3->Axis movement
4->Turret indexing
5->Main spindle, M tool spindle, Sub spindle received rotation command in excess of allowable maximum spindle speed in case of the following state.

1.A door interlock type
2.Interlock release switch ON
3.Except for single block

6->In a state of code 5, axis was made to transfer in excess
7->A turret rotation command was issued in MDI mode and in a state of code 5.
8->When a ceiling door was not close status, a turret indexing order by a turret indexing button on a subcontrol panel was
performed.

Okuma Alarm-A 8598 Ceiling door interlock