Okuma Alarm-A 8627 Long boring bar change protection
Code
1->The stock shutter open/close command is designated when the stock was not retract position.
2->The stock advance/retract command is designated when the stock shutter was not open position.
3->The stock upper/down command is designated when the stock was not retract position.
4->The stock clamp/unclamp command is designated when the stock was not advance position and the stock shutter was not open position.
6->The stock shutter advance/retract command is designated while the turret is not at the travel end of attachment position.
7->The stock clamp/unclamp command is designated while the turret is not at the travel end of attachment position.
8->The turret stock clamp/unclamp command is designated while the turret is not at the travel end of attachment position.
9->The stock clamp/unclamp command is designated while the turret is not at turret stock clamp position.
10->The turret stock clamp/unclamp command is designated while the stock is not the stock clamp position.
11->The stock clamp/unclamp command is designated while the turret is not at the home position.
12->The turret stock clamp/unclamp command is designated while the turret is not at the home position.