Okuma Alarm-A 8649 Measurement sensor unit interlock


Okuma Alarm-A 8649 Measurement sensor unit interlock
An attempt has been made to move the measurement sensor unit while its moving is not possible, or the measurement sensor unit moving impossible state has arisen during the movement.

Code
1->Measurement sensor unit advance command is designated when present-tool is not measurement sensor unit advance permission tool.
2->Measurement sensor unit advance command is designated when Z-axis is not on plus variable limit.
3->Measurement sensor unit advance command is designated when the sensor head is not in retract position.
4->Measurement sensor unit advance command is designated when the spindle is not in the stopped state.
5->Measurement sensor unit advance command is designated when the M-spindle is not in the stopped state
6->Measurement sensor unit advance command is designated when door interlock OFF and a front door were not closes.
7->Measurement sensor unit advance command is designated when the robot/loader is not in retract position.
8->Measurement sensor unit advance command is designated when APC arm is not in retract position.

Okuma Alarm-A 8649 Measurement sensor unit interlock