Okuma Alarm-B 2178 MCS Illegal command
The NC and the inverter unit exchange commands and responses through the servo link. In this communication, the NC sent an
abnormal or inexecutable command to the inverter unit.
Object
Axis name or none (spindle)
Character-string
None
Code
XXXXYYYY
XXXX=
11: Positioning mode Negative command value
12: Positioning mode Larger command value
13: Positioning mode RPositioning point table not transmitted
14: Positioning mode Non-rotating axis
15: Positioning mode Command format other than points
16: Positioning mode Positioning sub-mode error
21: Parameter change Parameter number out of specifable range
22: Mode Undefined mode
23: Mode Positioning/tool path mode condition
24: Coordinate system Coordinate system designation error
30: Unused bit is ON in the bit commands for controlling the S-link A buffer.
31: Unused bit is ON among the bit data in the S-link B buffer.
40: AT mode is selected without reception of time synchronization command.
YYYY= Error data
0:Program mode 1:Search mode 2:PH mode 3:Teach mode
Probable Faulty Locations
– Inverter unit not compatible with NC software
– Inverter unit control board
– NC software