Okuma Alarm-B 2212 G132/G133 command error
The cylindrical face cannot be determined in the G132, G133 side face contour generation mode because the X command values at the start and end point do not change. Or the cylindrical face cannot be determined because the X command value changes during the cutter radius compensation mode in the side face contour generation mode.
Code
None->During the G132, G133 side face contour generation mode
1->During the cutter radius compensation mode
Probable Faulty Locations
Program error
The X value in G132 or G133 command is different from the previously specified X value.
Program Example:
G00 X120
G132 Z150 C45 X135 L20
^^^^^X is not 120
Measures to Take
Correct the program.
Do not designate an X command in the G132, G133 block.