Okuma Alarm-B 2213 Program factor over


Okuma Alarm-B 2213 Program factor over
The buffer register storing program factors is full.
The number of commands in a single sequence is too large.
Or a problem with processing the GET and PUT commands. For the program factors, refer to the factor classification code table.

Object
SYSTEM

Code
1->More than 127 factor classification codes and factor parameters are designated.
2->More than 64 factor data are designated.
3->Move range of factor classification code and/or factor parameter stack is wrong. (This alarm does not occur usually.)
4->Move range of factor data stack is wrong. (This alarm does not occur usually.)

Probable Faulty Locations
1,2->Sequence in which an alarm has occurred
3,4->Error in control software
Program Example:
N010 ABC = 1 BCD = 2 …
BCD = 1
This expression has three factor classification codes and factor parameters.
An alarm of code 1 occurs if the total number of factor classification codes and factor parameters counted in this manner
exceeds 127.
An alarm of code 2 occurs if the total number of factor classification codes and factor parameters c counted in this manner
exceeds 64. (The factor data is not included in “=”, the number of factors is 2.)

Measures to Take
In case the alarm of code 1 and code 2 occurs, the number of commands in the sequence causing the alarm is too much; the
commands should be designated in two or more sequences. In case the alarm of code 3 and code 4 occurs, contact Okuma’s
software center.