Okuma Alarm-B 2244 Mistake in L command


Okuma Alarm-B 2244 Mistake in L command
Illegal L command
Numerical value of L command in circular interpolation mode is not: 0 < L<=99999.999The chamfering amount in thread cutting fixed cycle calculated from L and K (or I) commands is not 0 through 99999.999.Numerical value of L word in a gauging cycle is not 0 through 99999.999.In other modes, numerical value of L command is not:-99999.999<=L<=99999.999Or with cam turning specification models, when values are set for D (major axis of an oval) and L (lift amount of an oval) in the shape definition file (LSF), the D value is not proper.Code
None->The D value is not proper.
1->In the circular interpolation mode, L command does not satisfy: -99999.999<=L<=99999.9992->L value is negative in the circular interpolation mode.
Others->Hexadecimal number of L value in other than the circular interpolation mode

Probable Faulty Locations
L command value (for cam turning specification models)
Program Example:

G33 Z100 F1 L5 K-6

Measures to Take
Change the L command value to one which is permissible for the command having been designated when the alarm occurs.
Correct the D value.

Okuma Alarm-B 2244 Mistake in L command