Okuma Alarm-B 2266 Mistake in R command
In a block containing G181 through G184 or G189, either R=0 command is designated or an R command is designated with X and Z commands. Or the numerical value of X, Z or R does not fall within the following range: -99999.999<= X,(Z or R)<=99999.999Object
SYSTEM
Code
1->In the cutting target point command of R command, simultaneous designation of R with X and/or Z
2->In the cutting start point command of R command, simultaneous designation of R with I,J and/or K
3->In the cutting start point command or R command, R command exceeds the cutting target point
4->In the cutting start point command of R command, the cutting start point is away from the previous cutting target point
5->In the cutting target point command of R command and the G297 command, R command exceeds I,K command
6->In the cutting start point command of R command and the G297 command, R command has not exceeded the cutting target point
FFFFFFFF->No X, Z or R command
Others->Hexadecimal number of numerical value of designated X, Z or R
Probable Faulty Locations
Program error
Program Example:
G181 X60 R0 C0 K48 F40 :
Measures to Take
Check the X, Z, I, K, and R commands.
Related Specifications
Multi-machining model