Okuma Alarm-B 2267 Mistake in drilling cycle command
In a block containing G181 through G184 or G189, following three commands are designated simultaneously:
X, R and I, or Z, R and K
Object
SYSTEM
Code
1->Simultaneous designation of X, R and I, or Z, R and K
Probable Faulty Locations
Program error
Program Example:
G181 X60 R-27 I48 F40
Measures to Take
Check the X, Z, R, I and K commands.
[Related Specifications]
Multi-machining model