Okuma Alarm-B 2284 SCHEDULE PROGRAM program end


Okuma Alarm-B 2284 SCHEDULE PROGRAM program end
No program end command is designated in the schedule program.

Code
1

Probable Faulty Locations
Schedule program
Program Example:

N010 VSET V1=1
N020 PSELECT LOADER.MIN
N030 PSELECT SHAFT.MIN
N040 VSET V1=V1+1
N050 IF [V3 LE 10] N020

Measures to Take
Designate the END command at the end of the schedule.
Example:

N010 VSET V1=1
:
N050 IF [V3 LE 10] N020
N060 END
Okuma Alarm-B 2284 SCHEDULE PROGRAM program end