Okuma Alarm-B 2290 Program name not selected
Program name is incorrectly designated. The program name* differing from the one presently executed is designated.
* Command O**** is executed.
Object
SYSTEM
Code
Hexadecimal number of the ASCII code of four characters of the program name following address character O.
Probable Faulty Locations
Program sequence causing alarm
(Refer to program example on the following page.)
Program Example:
1)When calling a subprogram, designation of CALL is not made (same as in the case of MODIN).
N100 G00 N100 G00 N110 G01 N110 G01 N120 G00 N120 G00 CALL O100 O100 N130 G00 N130 G00 Normal Alarm
If a sequence No. is designated prior to O100, other type of alarm occurs.(Alarm B 429 Unusable: direct of left)
2)For the program which has two beginning sequences, the command used for skipping the second program name is not designated. GOTO statement is not designated.
O100 O100 G00 G00 G00 G00 GOTO N1 O200<-An alarm occurs when this sequence is executed. O200 G00 G00 G00 G00 N1 G01 N1 G01 G01 G01 :
Measures to Take
Do not execute the sequence which contains only a program name.
Related Specifications
User task 2