Okuma Alarm-B 2300 UGC TIF syntax
Illegal standard procedure statement (TIF statement) designated
TIF: Automatically generates tool interference check data based on the tool shape.
TIF [designation of tool interference check pattern, FZN, FZP, FXN, FXP]
Designation of tool interference check pattern: Specified by I for ID turning and by O for OD turning.
FZN, FZP, FXN, FXP: Used to specify the interference check range from the cutting edge datum point.
Code
User graphic internal code
Probable Faulty Locations
TIF statement in the user graphic command string of registered tool shape.
Program Example: DEF TOOL [1,L]
TIP [[0, 0],[1,0],[0,1]]
TIF [M,5,5,0,]
:
END
Measures to Take
If there is no TIF statement, add TIF statement.
If there is TIF statement, check it; correct the TIF statement.
Correct program:
DEF TOOL [1,L]
TIP [[0,0],[1,0],[0,1]]
TIF [0,5,5,0,]
:
END
Related Specifications
Graphic