Okuma Alarm-B 2308 UGC Coordinate data


Okuma Alarm-B 2308 UGC Coordinate data
Mismatch of the numbers of the left and right brackets, illegal factor code, inconsistency of the number of command coordinates

Object
SYSTEM

Code
1->Mismatch of the numbers of left and right brackets, illegal factor code, excess number of brackets with the commands excluding substitute statement
2->Mismatch of the number of left and right brackets, or inconsistency of the number of command coordinates with the commands excluding the substitute statement
3->Mismatch of the number of left and right brackets, illegal factor code, inconsistency of the number of command coordinates or excess number of brackets with the commands excluding substitute statement

Probable Faulty Locations
User graphic command
Program Example:
PF 3,[0,0],[10,0],[0,10],[7,8],4
:

Measures to Take
Check and correct the user graphic command format.
:
PF 3,[0,0],[10,0],[0,10],4
:

Related Specifications
Graphic

Okuma Alarm-B 2308 UGC Coordinate data