Okuma Alarm-B 2354 CHAMFERING L over
In chamfering commands, designated L value is larger than the axis movement distance.
Object
SYSTEM
Code
Hexadecimal number of axis movement distance
Probable Faulty Locations
Program error
Program Example:
N009 G01 X97 Z100 N010 G75 X100 L-5 F0.5 N011 Z50
Measures to Take
Check the chamfer size and the axis movement amount.
In the example program above, axis movement amount is “3” which is smaller than the chamfer amount “5”.