Okuma Alarm-B 2359 NOSE-R COMP. No spec.


Okuma Alarm-B 2359 NOSE-R COMP. No spec.
G41 and G42 calling for tool nose radius compensation mode is designated although the control has no nose radius compensation specification.

Object
SYSTEM

Probable Faulty Locations
Program error
Program Example:

N010 G40 X-- Z--

Measures to Take
Delete the G commands related with the nose R compensation function, G41, G42 and G40, from the program.