Okuma Alarm-B 2364 NOSE-R COMP. Entrance command error
Tool nose radius compensation mode entry is intended in other than permissible manner, and compensated point cannot be calculated.
Object
SYSTEM
Code
None->G41 or G42 is designated in other than G00 or G01 mode.
10->The value commanded in the G41 or G42 block and the value commanded in the following block are the same.
11->X or Z command is not designated in the block following G41 or G42 block.
40->G40 is designated in the block following G41 or G42 block.
Probable Faulty Locations
Program error
Program Example:
N010 G42 X50 Z55 N011 X50 Z55
Measures to Take
Check the G42 block and the following block.
In the example program above, X and Z commands in the G42 block and the following block are identical; correct the program.
In this case, delete the N011 block since it is not necessary.