Okuma Alarm-B 2373 LASER MEASUREMENT condition
Conditions in which the laser measurement commands LMW and LMV have been executed are not correct.
Object
SYSTEM
Code
1->The command is designated for A and B
2->Both X and Z commands are designated in the same block.
3->The command is designated in the nose R compensation mode.
4->The command is designated in the LAP mode.
5->Q command is designated with the LMW command.
6->The measuring range includes the limit.
7->The identical point is designated as the start and end points of measurement.
Probable Faulty Locations
Program error
Program Example:
: LMW Z100 X100 :
Measures to Take
Check the contents of error in the program from the alarm code number; remove the cause which intervenes the execution of
the laser measurement command.
LMW Z100 LMW X100
Related Specifications
Inductosyn pitch error compensation