Okuma Alarm-B 2479 Contour generation calculation error
Floating point calculation error in the preparation processing for the function generation of the G101, G102 and G103 main task.
Object
SYSTEM
Code
XYY
YY:
bit0->Overflow in converting into integer
bit1->Exponential underflow
bit2->Exponential overflow
bit3->Calculation of root of a negative number
bit4->Division by 0
bit5->Angle overflow for SIN, COS, TAN and COT
X:
1->Error in G101 processing
2->Error in G102/G103 processing
Probable Faulty Locations
Program error
Measures to Take
Check the contents of error in the program from the alarm code number; remove the cause which intervenes the execution of create process command.
Related Specifications
Create process