Okuma Alarm-B 2495 Inverse time feed command format


Okuma Alarm-B 2495 Inverse time feed command format
A G-code that cannot be specified in the inverse time feed mode is specified.
Home position command(G20/G21/G24/G25)
Contour generation function command(G101/G102/G103/G132/G133)
Circular thread cutting command(G112/G113)
Fixed cycle command(G31/G32/G33/G34/G35)
Torque skip command(G22)
Lathe Auto-Programming(LAP) command(G80-G88)
Z-W axis superimpose control command(G117)
W-axis control ON command(G145)
Tool nose radius compensation(G41/G42)
Compound fixed cycle command(G71-G74/G178/G179/G181-G191)
Positioning overlap(G15)
Gauging cycle(G30))

Object
SYSTEM

Code
None

Probable Faulty Locations
Program error.

Measures to Take
Correct the program.

Okuma Alarm-B 2495 Inverse time feed command format