Okuma Alarm-B 2501 Recovering synchronous error


Okuma Alarm-B 2501 Recovering synchronous error
An alarm message indicating that the synchronization error correction mode or synchronized position shift setting mode has been entered for synchronized axis control.

Object
None

Character-string
None

Code
The synchronization error as expressed by hexadecimal notation

Probable Faulty Locations
Indicates that the system is now in a mode for correction of synchronization errors.

Example of operation
Set bit 0 or 1, optional parameter No. 49 to ON to enter the synchronization error correction or synchronized position shift setting mode.

Measures to Take
This alarm only notifies the operator of the mode and needs no special action.
Exit the mode to erase the alarm.