Okuma Alarm-B 2542 Feed axis retract function command
Feed axis retract function command is incorrect.
Object
None
Character-string
None
Code
X
1->RT command value is out of the range from 0 to 4.
2->After G268 command is instructed, G140/G141 command is assigned in without G267 command.
Probable Faulty Locations
Program error
Measures to Take
It amends programming error.