Okuma Alarm-B 2543 Turret index error position
Axis feed command was issued in turret index error position.
Object
SYSTEM
Code
None
Measures to Take
1)The turret is moved to X-axis or Z-axis plus variable limit position in MANUAL operation mode, and the turret index command is executed.