Okuma Alarm-B 2546 MULTI-MACHINING CYCLE LK


Okuma Alarm-B 2546 MULTI-MACHINING CYCLE LK
Designated LK value is not: 0 < LK <= 99999.999LK: Pecking amount in deep hole synchronization tapObject
SYSTEM

Code
Hexadecimal number of designated LK value

Probable Faulty Locations
Faulty program (compound fixed cycle block)
Program Example:
G178 X40 Z80 C0 I46 F40 L30 LD=10 LK=-2

Measures to Take
Check the LK command in the compound fixed cycle block.
G178 X40 Z80 C0 I46 F40 L30 LD=10 LK=2

Related Specifications
Multi-machining model

Okuma Alarm-B 2546 MULTI-MACHINING CYCLE LK