Okuma Alarm-B 2562 Tool posture fluctuation reduction
Tool posture fluctuation reduction is wrong.
Object
None
Character-string
None
Code
1->It instructed in other G, M code, and the address character at the same time in when instructing in G445/G444 command of Tool posture fluctuation reduction mode.
2->Tool posture fluctuation reduction mode ON command while it was not the tool center point control mode OFF.
3->Tool center point control mode OFF command while it was the Tool posture fluctuation reduction mode ON.
4->TFA,TFB,TFC,TFP,TFQ,TFR command is out of range.
5->It instructed in Permissible level of rotation axis A that was not the object of Tool posture fluctuation reduction.
6->It instructed in Permissible level of rotation axis B that was not the object of Tool posture fluctuation reduction.
7->It instructed in Permissible level of rotation axis C that was not the object of Tool posture fluctuation reduction.
Probable Faulty Locations
Tool posture fluctuation reduction command(G445,G444) in a program.
Measures to Take
Check Tool Posture Fluctuation Reduction command(G445,G444) in the program.