Okuma Alarm-B 2623 B-axis no spec.


Okuma Alarm-B 2623 B-axis no spec.
B-axis G code (G146/G147) is designated although the control has no B-axis specification.

Object
SYSTEM

Probable Faulty Locations
Program error
Program Example:

N010 G147

Measures to Take
Eliminate G146/G147 from the program.