Okuma Alarm-B 2624 Tow-along steady rest type-B no spec
G153 is designated although the control has no tow-along steady rest specification.
Probable Faulty Locations
Program error
Program Example:
N010 G153 W100
Measures to Take
Delete the tow-along steady rest command G153 from the program.