Okuma Alarm-B 2794 Mist air lube unit


Okuma Alarm-B 2794 Mist air lube unit
The mist air lubrication unit turned OFF the normal operation signal or turned ON the unit abnormal signal.

Code
1->The X-/Z-axis oil mist lubrication drop sensor remained ON for more than 2[s].
2->The X-/Z-axis oil mist drop lubrication sensor was not turned ON at all for two consecutive cycles of X-/Z-axis oil mist lubrication pump drive air ON.
3->When the power is supplied, the air ON cycle is performed for driving X-/Z-axis oil mist lubrication pump. This cycle was repeated 100 times before the X-/Z-axis oil mist drop lubrication sensor came ON three consecutive times.
4->The cumulative operation time of X-/Z-axis oil mist lubrication drive air ON output exceeded 24 hours with the X-/Z-axis oil mist coolant level normal signal OFF.
5->The pressure normal signal for driving X-/Z-axis oil mist lubrication unit went OFF when the X-/Z-axis oil mist lubrication operation air ON output was ON.