Okuma Alarm-B 2807 Invalid M code


Okuma Alarm-B 2807 Invalid M code
M commands are not used properly.

Code
1->M1059 command was issued after the MT command.
2->M1059 command was issued when the active tool number was an adaptor.
3->M1059 command was issued in a position other than the ATC start position.
6->M1074 command was issued after the MT command.
7->M1074 command was issued without any next tool command.
8->M1074 command was issued in a position other than the ATC start position.
9->M1074 command was issued when the active tool number was an adaptor.
10->M1074 command was issued without any active tool command.
11->M1075 command was issued without MT command.
12->M1075 command was issued without any next tool command.
15->M1074, M1075, M1078, or M1100 was specified when no attachment is mounted in the swivel head.
16->M1100 command was issued after the MT command.
17->M1100 command was issued without any active tool command.
18->M1100 command was issued in a position other than the ATC start position.
20->M06 command was executed with an M1075 command when the active tool was a vertical spindle tool.
21->M06 command was executed without any M1075 command when the active tool was a horizontal tool. Or M77 command was executed without any M67 command when the active tool was a vertical tool.
22->M06 command was executed with an M1075 command when the active tool was a horizontal large-diameter tool.
30->Thru-spindle air blow command was issued during spindle rotation.
31->Thru-spindle coolant command (M1071/M1072/M1082/M1119) was issued through the spindle tool does not have an oil hole.
32->Thru-spindle coolant was specified when the vertical spindle tool clamp signal is OFF.
33->Thru-spindle coolant command was issued though the active attachment has no oil hole.
34->An active attachment was instructed in thru-spindle air blow command by the swivel head attachment at the horizontal axis mode.
36->AAC sequence number other than 1 was specified.
37->Touch sensor operation command was issued with the X-axis out of the area where it can activate the touch sensor.
38->Touch sensor advancement command was done when cross-rail was outside range where the touch sensor was able to work.
41->M spindle turnover mode ON/OFF command was issued when the spindle was running.
42->M1042..M1045, M1047, M1048 command was executed when attachment must not rotate.
45->M1030..M1039 was issued within the range where the position of X-axis was able to be gone up and down the cross-rail.
46->M1030..M1039 was issued in the state that was not right edge when the ATC unit was a turn around the magazine side.
47->M1030..M1039 was issued in the state that was not the touch sensor retract edge.
48->M1042..M1045, M1047, M1048 command was issued during M spindle rotation.
49->M1042..M1045, M1047, M1048 command was issued though X-axis is not located in the attachment rotation range.
50-> M1047..M1048 command was executed without RH command.
51->Attachment rotation command was issued to an attachment which cannot rotate.An angle different from the previous one was specified while the attachment is being indexed.
52->A wrong crossrail positioning command was entered.
53->The tool disapprove of ATC is in M-spindle.
54->Angle head coolant command was issued though the spindle tool was not an Attachment tool.
55->Thru-spindle coolant command was issued when the spindle tool was an Attachment tool.

Okuma Alarm-B 2807 Invalid M code