Okuma Alarm-D 4710 Parameter non set


Okuma Alarm-D 4710 Parameter non set
There is an Machine Parameter 0, which should have been set otherwise, at Control Software Installation.
Note: Right after Control Software Installation, Initial Data is set 0. Consequently, right after Control Software Installation, this Alarm is triggered.

Code
1->MC USER PARAMETER NO.3 SPINDLE “1.Allowable chuck rotation speed”, to be set.
2->MC SYSTEM PARAMETER NO.2 TURRET/DOOR “1.Number of tools on turret A-side”, to be set.
3->MC SYSTEM PARAMETER NO.2 TURRET/DOOR “2.Number of tools on turret B-side”, to be set.
4->The boundary of the tailstock motion enabled/disabled range is set to ‘0’.
5->Turret A rotation enabled range 1
6->Turret A rotation enabled range 2
7->Turret B rotation enabled range 1
8->Turret B rotation enabled range 2
9->The parameter is not setting about turret index position mounted work detected sensor.
10->Auxiliary tool no. ( Long boring bar )

Measures to Take
Set necessary parameters in parameter setting mode.
Codes 2 and 3 become effective when the power switch is turned ON again.

Okuma Alarm-D 4710 Parameter non set